An unplanned roof fall has occurred, above the anchorage, in a previously rehabilitated area, 2000+ outby the working section, in the N0 3 entry, approximately 30 feet outby survey spad 1417. The fall was approximately 80 feet long, 20 feet wide and 5 foot high. Ventilation and/or the transportation of men were not affected.