Roof fall was found in the #9 seam in the 6th South Panel, #6 entry crosscut 80-81. The fall measures 80' long by 18' wide by 6' high. Primary support in that area is 5' stick pins. The fall is not in an escapway and ventilation is not affected. The fall will be dangered out, with no plans of cleaning up.