A roof fall occurred in E#3 @ station 30+10 in the Old 5A intake. The roof fall did not affect ventilation, cause personal injury or affect passage. The roof fall measured 27'x 31' x 6'. The area had been supported with 6' roof bolts. This report is being filed to abate a citation, we do not feel that it is reportable. Area had been dangered and timbered out prior to the fall.