A roof fall occurred in the last open x-cut in #0 Entry in the G-Butt working section MMU 002-0. 6' fully grouted Super twists bolts were being used. 5 bolts out of two rows were pulled out of rock and approx. 6' of unsupported roof fell this was at the face of #0 entry.