FALL OF ROOF OR BACK

220121110010 · 04/10/2012 · Neco Energy Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Jack H Ealy; Ralph Napier; John D North - JackrockLLC only8/27/99-5/
Operator
Neco Energy Inc.
Mine
1519282

Narrative

A non-injury roof fall occurred at approx 8:50 AM. 2nd cross cut on Ginsong Mains. 18' wide x 5' thick x 38' long.