At approximately 11:45am, a roof fall was identified on the 3 left section ( 3 ) breaks inby 8c Head in the #4 neutral entry. The fall was approximately,20'W x 20'L X 5'-6'H. The fall was supported with 5' torque tension bolts. The fall will not be cleaned up and has been dangered off and timbers set.