This mine has experienced a non-injury un-intentional roof fall outby the working section. The fall occurred on the intake of Six North which leads to 001 section. The fall is approximately 9 feet thick, 60 feet long and 20 feet wide. This area was initially supported with 60 inch fully grouted rods and 8 foot cable bolts. Laminated shale gave way from deterioration.