← MSHA accidents

FALL OF ROOF OR BACK

220121710041 · 06/18/2012 · ICG Hazard, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
ICG Hazard, LLC
Mine
1518991

Narrative

This mine has experienced a non-injury un-intentional roof fall outby the working section. The fall occurred on the intake of Six North which leads to 001 section. The fall is approximately 9 feet thick, 60 feet long and 20 feet wide. This area was initially supported with 60 inch fully grouted rods and 8 foot cable bolts. Laminated shale gave way from deterioration.

Source

Authoritative
MSHA Open Government Data
Machine