# FALL OF ROOF OR BACK
> MSHA accident `220121940001` · 07/08/2012 · Consolidation Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consolidation Coal Company
- **Mine:** [4404856](https://api.ai-analytics.org/mine/4404856)
## Narrative

an unintentional roof fall was discovered at approximately 6:10 am in number 6 entry on the 3 east mains at break No 77. All approaches to the fall were timbered off. The fall did not interrupt ventilation and will not be cleaned up. The fall was approximately 11 feet high, 30 feet long, and 18 feet wide. The fall was in the intersection.

---