← MSHA accidents

FALL OF ROOF OR BACK

220122010011 · 07/16/2012 · CONSOL of Kentucky Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
CONSOL of Kentucky Inc.
Mine
4609424

Narrative

A rock fall was discovered in the Intersection behind the power center at #2 break in the #5 entry along the #2 belt the fall was estimated to be 5' thick X 18' wide X 20' long no injuries and no ventilation controls or equipment was affected. This fall will not be cleaned up and the area has been cribbed/timbered and dangered off.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown