← MSHA accidents
FALL OF ROOF OR BACK
220122060007
· 07/06/2012 · Newtown Energy Inc
Details
Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years
Operator
Controller (parent)
Patriot Coal Corporation
Operator
Newtown Energy Inc
Mine
4608759
Narrative
During the preshift examination of all underground workings after a 7 day power outage a roof fall was discovered in the 1 South Mains track entry from break 28 to 29. The fall was 5 ft thick and 95' long. The fall was reported at 9:15 a.m.