# FALL OF ROOF OR BACK
> MSHA accident `220122140005` · 07/31/2012 · Consolidation Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consolidation Coal Company
- **Mine:** [4601436](https://api.ai-analytics.org/mine/4601436)
## Narrative

A fall of roof occurred at spad location 338+00 on the old main line track at the Whittaker Portal. The inby corner on the wire side fell out and pulled additional material out of the cross-cut with it. The approximate size of the roof fall is 8 feet high, 8 feet wide and 15 feet long.

---