A roof fall was discovered on the 1- North Mains. the roof fall is located in the #5 entry and crosscut at break #5. The roof fall has been dangered off. The fall has not affected the ventilation at this mine. The fall will not be cleaned up. The approx. dimensions of the fall is 20' w. x 20-30' l. x 6' thick.