An unintentional roof fall occurred and was discovered by mine personnel. No injuries occurred. No equipment damage occurred. The roof fell approx. 6 to 8 feet above the coal seam, 16 feet in width x 30 feet in length. The fall area had been roof bolted and rib bolted to plan. The roof fall will be cleaned up and re-supported with a steel arch system.