← MSHA accidents

FALL OF ROOF OR BACK

220123000003 · 10/21/2012 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4404856

Narrative

An unintentional roof fall was discovered at approx 5:50am. In the number 5 entry on the Grassy Creek Mains at break 54. The fall extended to the number 6 entry intersection by excluded the number 6 entry. All approaches to the fall were timbered off. The fall did not interrupt ventilation but will be cleaned up. The fall is approx 110' long, 20' wide and 12'high.

Source

Authoritative
MSHA Open Government Data