A unplanned roof fall occurred at this location. Fall was located at #162 Break in the #3 entry, 10,800' from the active 001/002 section. Area was originally supported with 5' torque tension bolts. Fall measured 60' L. x 20' W. x 6' H. Did not affect ventilation or passage of persons. Federal and State Agencies notified.