A roof fall was identified by a fireboss on the old 1st Rt. Section at break 193 near spad #999. The fall was approx. 18'W X 250'L X 8'-10'H. The area was mined approx. 3/21/12 and was supported with 4' fully grouted resin bolts. The area will not be cleaned up and the area has been dangered off and timbers set.