A roof fall measuring 32'L X 18'W X 8' thick was discovered 500' outby the working section in the return near survey point 70273. The failure was due to laminated coal/rock streaks above the 6' torque tension supports. The fall affected ventilation. An MSHA control order was issued the roof was resupported and ventilation was re-established.