A roof fall occurred in the 3rd Main East intake between x-cut 30-31 in the pillar line #7 intake entry. The fall meas. 25'x6'x19' and was caused by a hidden slip in the mine roof. The area was supported by 6' tension glue bolts and was mined in 3/08. There were no injuries and no EQ. involved and ventilation was not affected.