An unplanned roof fall was found by Block Foreman in the #6 entry at crosscut #21 of the 1st right panel off of #5 belt on #2 section. The fall was approximately 20' length X 22' width X 12' high. No injuries or entrapment involved. No escapeways, equipment or ventilation effected. This is an abandoned panel and the #6 entry is not traveled.