Bearing housing bolts broke in scalping screen. EE replaced broken bolts. Nylon strap was attached to shiv which was standing vertical. Employee let go of the shiv to connect the chain come along to the strap. The shiv fell over & down a step hitting the top of employee's right foot. JSA had been done but falling hazard not identified. Medical attention not requested until 3-12-13.