← MSHA accidents

HOISTING

220130950010 · 04/02/2013 · Mountain Coal Company, L.L.C.

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
Mountain Coal Company, L.L.C.
Mine
0503672

Narrative

A power surge on the feed line tripped circuit breakers to the hoist. The main external circuit breaker was reset but not the internal circuit breaker. A qualified person was sent from the mine site to reset the internal circuit breaker but due to travel time, the hoist was down for more than 30 minutes. When the internal breaker was reset at 10:10, the hoist was fully functional.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown