# FALL OF ROOF OR BACK
> MSHA accident `220131000008` · 04/01/2013 · KenAmerican Resources Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** KenAmerican Resources Inc
- **Mine:** [1517741](https://api.ai-analytics.org/mine/1517741)
## Narrative

It was determined that the roof had deteriorated which caused the roof to fall to the mine floor. The fall was 70' long starting in the intersection of cross cut #20 along the 1st Southwest mains in the #5 entry going toward #4 entry. The fall was 18' wide and 15' plus in height.

---