During the preshift exam a roof fall was found in the Primary Escapeway. The fall was reported outside and Msha was notified. The area was dangered off until inspected. The fall was approx. 80 feet long, 4-6 foot thick in the #6 heading. 55ton jacks and wooden timbers were installed to protect miners and the area.