Unintentional roof fall occurred and was discovered by mine personnel. No injuries or equipment damage occurred. The fall area measures 16 feet wide x 30 feet long x 7 to 8 feet high, above the coal seam. The fall area had previously been roof & rib bolted to plan. This fall area has been ""dangered off"" with ""breaker posts"", set on both accessible sides of the fall.