A small roof fall was discovered during the weekly exam located approx 1100' outby the working section. The roof fall is in the #1 entry off the mains going into a panel that has been pillared. The roof fall appears to be contained to that intersection. There were no injuries associated with this fall. This fall measures approx 20' wide x 20' long x 10' thick.