A fall was discovered at #3 Mains Section (#15 Block, #3 Intersection). The fall was 13,800' outby the closest loading point. The area was bolted with 12' cable bolts and 6' SuperTwist bolts. Ventilation, people, and equipment were not affected by the fall.