# ELECTRICAL
> MSHA accident `220131920023` · 07/05/2013 · Tunnel Ridge, LLC
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)
- **Activity:** Hang or reposition tubing
- **Injury source:** CONDCTR,ELCT,CBL,TROL POL
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 0
- **Mine experience:** 2.27 years
## Operator
- **Controller:** Alliance Resource Partners LP
- **Operator:** Tunnel Ridge, LLC
- **Mine:** [4608864](https://api.ai-analytics.org/mine/4608864)
## Narrative

EMPLOYEE WAS HANGING VENT TUBING IN THE #3 ENTRY OF THE 2 RIGHT SECTION. A SHUTTLE CAR SNUBBED IN SAME ENTRY HAD A WORN SPOT IN OUTER JACKET THAT LET LEADS CONTACT METAL SNUB. THIS RESULTED IN THE WIRE MESH ON ROOF BECOMING ENERGIZED. WHEN EMPLOYEE WENT TO HANG METAL ""DOG CHAIN"" ON ROOF, HE WAS SHOCKED. EMPLOYEE REPORTED MOMENTARY LOSS OF CONSCIOUSNESS.

---