← MSHA accidents

ELECTRICAL

220132050008 · 07/15/2013 · Ohio American Energy Incorporated

Details

Degree of injury
NO DYS AWY FRM WRK,NO RSTR ACT
Classification
ELECTRICAL
Accident type
Contact with electrical current
Occupation
Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer
Activity
Electrical maintenance
Injury source
CONDCTR,ELCT,CBL,TROL POL
Nature of injury
ELECTRIC BURN-CNTACT BURN
Body part
HAND (NOT WRIST OR FINGERS)
Days lost
0
Mine experience
1.71 years

Operator

Controller (parent)
Robert E Murray
Operator
Ohio American Energy Incorporated
Mine
3304550

Narrative

Employee was attempting to splice a miner car cable. The cables were twisted and not easily identified, he cut the wrong cable that was energized. Cause of injury wasn't identifying the proper cable that was locked out and tagged. Compliance with company rules was a factor, miner proficiency may be a factor, PPE was a factor, and mining practices/systems could be a factor.

Source

Authoritative
MSHA Open Government Data
Machine