A roof fall occurred at 10:05 AM at 10+50 entry 6 in 8LMS MMU 010. Fall was in a four way intersection that had been mined May 8, 2013. Fall was 18' wide X 18' long X 8' high. Fall was caused by a transition zone that went from 4' pins t o8"". No injury resulted.