← MSHA accidents

HOISTING

220132350011 · 08/19/2013 · Nevada Copper Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Nevada Copper Corporation
Operator
Nevada Copper Inc.
Mine
2602711

Narrative

On 8-19-13 while operating a shaft sinking operation at the Pumpkin Hollow Mine. At 7:25PM the hoist experienced a loss of power due to an electrical storm. Miners were evacuated using the Grove 890rt crane with manbasket. After the electrical dept. trouble shot & reset the hoist. The hoist resumed normal operations at 9:30 PM. MSHA was notified via the 1-800 Number at at 8:05 PM.

Source

Authoritative
MSHA Open Government Data
Machine