An unintentional roof fall was found by mine examiner one break inby spad 1039 in the #7 Entry of #1 SE Mains at approximately 11:45am. Fall measured 18x24x6 1/2. All approaches have been cribbed/timbered and dangered off. Ventilation not interrupted. MMU's in non-producing status since August 16,2013.