A roof fall occurred on the Sub-Mains section (#13 Block, #23 Belt, #2 Entry). The fall area was approximately 16' wide and was bolted with 6' torque tension bolts and 12' cable bolts. Cribs were set at the fall location. No equipment, ventilation, or persons were affected.