A roof fall had occurred on our #2 Main Belt at 8+83. The fall was 26 feet long, 17 feet wide and fell above the roof horizon of feet. Area was roof bolted with two piece roof bolts, headers and pie pans. Fall was caused by deterioration of the mine roof through weathering.