An unintentional roof fall occurred and was discovered by mine personnel. No injuries or equipment damage occurred. Fall area measured 6 feet highx 16 feet long x 16 feet wide. This fall area had previously been roof and rib bolted to plan , with roof screen installed. This fall material consisted of laminated shale with a clay seam parting , with water present.