A roof fall was found at 8:50am in our S7-1st Right Panel at crosscut #12, entry #6, a primary escape way. The fall measured 18'x18'x6'. The MSHA Hotline was notified at 8:55am. This fall did not impede passage of miners, affect ventilation or injure any miner.