On 10/31/2013 at approximately 13:25 an unplanned roof fall occurred at cross cut #106 on the Main West, entry #4, beltline. The primary means of support in the area was 6' point anchor bolts, and the supplemental means of support was 10' point anchor bolts. The fall was approximately 12' high. The openings approaching the fall are approximately 18' wide.