# FALL OF ROOF OR BACK
> MSHA accident `220133470016` · 12/11/2013 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall occurred at 79+25 in 4 west section in #2 entry inby the tail. The fall measured approx 32' in length, 16' wide and 15' in height. Area was bolted with install III resin assisted bolts, CC cable bolts in every other row along with screen and bacon straps. Contributing factor may have been physicals characteristics of strata and low cover.

---