An unexplained roof fall (slip) occurred. No equipment, entrapment, or Airways were interrupted. The Slip was 5' wide X 4.5' thick and 15' long. The location of the slip was at break 217 on #12 belt. This fall was not above anchorage, but the current MSHA inspector felt we should report it.