While working on his communication line an electrican identified a roof fall in the #4 entry near spad #2775. The fall was approx. 20'W X 30'L X 3'-4'H the area was mined approx. March 1992. The area was supported with 4' fully grouted resin bolts and will not be cleaned up. All approaches have been dangered off and timbers have been set.