ROOF FALL - Occurred in the #3 entry, sat down on the #2 longwall crusher and fell above the 6 foot roof bolts in the #4 entry. There was an open area in the #3 and #4 entry that allowed positive air flow to the face. No injuries occurred at the time of the roof fall and access to the escape ways were maintained.