← MSHA accidents

ELECTRICAL

220140850033 · 03/21/2014 · El Segundo Coal Company, LLC

Details

Degree of injury
NO DYS AWY FRM WRK,NO RSTR ACT
Classification
ELECTRICAL
Accident type
Flash burns (electric)
Occupation
Crane operator, Mobile equipment operator (MEO), Dragline operator, Dropball operator, Rigger
Activity
Inspect equipment or mine
Injury source
ELECTRICAL APPARATUS,NEC
Nature of injury
ELECT.ARC BURN-NOT CONTAC
Body part
EYE(S) OPTIC NERVE/VISON
Days lost
0
Mine experience
29.46 years

Operator

Controller (parent)
Peabody Energy Corporation
Operator
El Segundo Coal Company, LLC
Mine
2902257

Narrative

IE was inspecting #1 drag generator on BE-1570W dragline when the generator brushes flashed. The flash resulted in eye exposure to the electrical arc. IE was seen by ER doctor. No blisters or foreign material were detected under ultraviolet light, but the ER doctor prescribed an antibiotic ointment as a precautionary measure until the IE could be seen by an optometrist.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown