An unplanned roof fall occurred beginning inby spad 348 and extending up to the next crosscut then continuing through the crosscut between 1 & 2 entries just short of spad 347. The fall measured 19'W X 120'L by 8'H. No injuries occurred and passage of men and airflow were not affected. This fall was in an entry not normally traveled by the weekly examiner.