# ELECTRICAL
> MSHA accident `220141600006` · 05/28/2014 · Warrior Coal LLC.
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)
- **Activity:** Roof bolter, Tramming
- **Injury source:** UNDERGRD MINING MACHINES
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 0
- **Mine experience:** 0.12 years
## Operator
- **Controller:** Alliance Resource Partners LP
- **Operator:** Warrior Coal LLC.
- **Mine:** [1517232](https://api.ai-analytics.org/mine/1517232)
## Narrative

Employee was ""squaring up"" pinner into No 3 right x-cut with the side control tram levers when pinner shocked him and lost power. Investigators discovered a grounded cable on the reel and ineffective insulated tram lever control covers due to age and wear contributed to employee receiving shock.

---