# FALL OF ROOF OR BACK
> MSHA accident `220142190016` · 07/27/2014 · Bowie Resources LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Wolverine Fuels LLC
- **Operator:** Bowie Resources LLC
- **Mine:** [0504591](https://api.ai-analytics.org/mine/0504591)
## Narrative

On 7/27/14 2-feet to 2.5 sagged onto the top of the longwall stage loader and prevented the loader from advancing normally.  The area of sagging roof was approx. 4-feet wide by 70-feet long. The #3 entry of the B-15 headgate panel had been supported with 8-foot fully grouted resin bolts on 5-foot centers with steel roof mesh and cable truss bolts on 5-foot centers.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*