A roof fall occurred in the 3rd main east at X-cut # 35 in the 2nd 54 belt line. The fall measured 60'x20'x9' and was caused by a hidden slip in the mine roof. The area was supported by 6' tension rebar bolts and 8' cable bolts in the intersection. The area was mined in March of 2008. There were no injuries, no equipment involved and ventilation was not affected.