A roof fall was found at 12:50 PM on 8/15/2014 of the Buckshot Mains of the Baker room section. Roof fell above anchorage from survey station 12599 to survey station 12600. This was in the # 6 and 7 entry intake. Stopping line was set over and intake was re-established.