An unintentional roof fall occurred and was discovered by mine personnel. No injuries or equipment damage occurred. Fall area measured 13 feet wide x 16 feet long x 6 to 7 feet high. This fall area had previously been roof and rib bolted to plan, with the addition of supplemental roof support in the form of wire screen,& tensionable slings.