A roof fall was found at 2:31PM on 11/3/14 at xc 58 entry 3 main west #2 belt. Area had been mined June of 2006 and supported with 8' full resin pins. Fall was in a 4-way intersection and measured 20'X20' X8 high. No injury resulted fall will be cleaned up and re-supported according to approved plan.