EE was replacing impeller bars in Crusher. While exiting crusher, the wedge locking the rotor in place came loose. The rotor appears to have been out of balance due to a missing set of impeller bars. The unbalanced rotor begun to spin & the EE's boot caught between the wall & the rotor pulling him downward. EE suffered left leg lacerations & two crushed toes on right foot.