A roof fall occurred on this date. The fall is located on 3-North-1 in the #2 entry at crosscut #7. All miners located inby the fall were brought outby the fall area and the secondary escapeway was rerouted. The fall area was previously supported with 5' Hy-tech bolts and supplemented with cable bolts. The fall will be cleaned up and the area resupported.